| Dial size : |
DN100 / DN150 |
| Range : |
25 mbar…0...25 bar |
| Mounting pattern : |
Direct, Bottom connection |
| Process connection : |
¼" NPT (F) x 2 Nos. |
| Ingress protection : |
IP 65 |
| Execution : |
Dry |
| Chamber type : |
Pattern 1 (0...0.6 bar up to 0...25 bar) |
| Accuracy : |
CL 2.5 |
| Ambient Temperature : |
-40...+65°C (without dampening liquid)
-20...+65°C (with dampening liquid) |
| Service Temperature : |
200°C max. |
| Static pressure limits : |
2 bar up to 250 mmWC
6 bar above 250 to 600 mmWC
10 bar above 600 to 6000 mmWC
40 bar above 6000 mmWC to 4 bar
60 bar above 4 bar |
| Sensing Elemnets : |
Diaphragm |
| Case & Ring Material : |
AISI 304 SS (Bayonet type) |
| Diaphragm : |
AISI 316L SS |
| Chamber : |
AISI 304 SS |
| Fastener : |
AISI 304 SS |
| Movement Mechanism : |
AISI 304 SS |
| Dial : |
Aluminum, black graduation on white background |
| Pointer : |
Micro-zero adjustable, aluminum, black powder coated |
| Gaskets, Blow off disc & filling plug : |
Neoprene / NBR |
| Accuracy : |
CL 2.5 |
| Window : |
Shatterproof safety glass |
| Dampening liquid : |
Glycerin 99.7% |