| Dial size : |
DN100 / DN150 |
| Range : |
0 to 100 mBar … 0 to 200 Bar |
| Mounting pattern : |
Direct, Bottom connection |
| Process connection : |
¼" NPT (F) x 2 Nos. |
| Ingress protection : |
IP 65 |
| Execution : |
Dry |
| Accuracy : |
CL 1.6 (AISI 316L SS ) - Accuracy will be 2.5 with Hastealloy C and monel 400 Diaphragm |
| Ambient Temperature : |
-40...+65°C (without dampening liquid)
-20...+65°C (with dampening liquid) |
| Service Temperature : |
100°C max. |
| Static pressure limits (on either side) : |
40 bar / 100 bar / 200 bar |
| Over-pressure safety : |
200 bar for ranges 0...0.4 bar up to 0...40 bar. |
| Zero shift : |
Max. ± 2.5 % at 20°C and max. static pressure. |
| Sensing Elemnets : |
Double diaphragm, Internal stop without o-ring
≤ 16 bar - AISI 316L SS, > 16 bar Inconel 718 |
| Case & Ring Material : |
AISI 304 SS (Bayonet type) |
| Diaphragm : |
AISI 316L SS |
| Chamber : |
AISI 304 SS |
| Fastener : |
AISI 304 SS ( PN 100 bar max.)
Alloy steel zinc coated |
| Movement Mechanism : |
Stainless Steel |
| Transmission chamber dampening liquid : |
Silicon oil |
| Chamber sealing gaskets : |
Viton |
| Dial : |
Aluminum, black graduation on white background |
| Pointer : |
Micro-zero adjustable, aluminum, black powder coated |
| Gaskets, Blow off disc & filling plug : |
NBR |
| Window : |
Shatterproof safety glass |
| Purging plugs : |
2 x ¼” NPT (M), AISI 316 SS |